Loading...
Rheem RPNL018JAZ/RHLLHM2417JA

Rheem Classic 1.5 Ton 14 SEER R410A High Efficiency Heat Pump Split System RPNL018JAZ/RHLLHM2417JA 

SKU: RPNL018JAZ-RHLLHM2417JA


List Price: $2,981.00  

Price: $2,237.00

You save: $744.00 (25%)
-25%
In Stock

Select a Heat Option

This Product Includes:

  • Installation Instructions
  • One Rheem Outdoor Unit - RPNL018JAZ
  • One Rheem Indoor Unit - RHLLHM2417JA
  • Pre-charged R-410A
  • Free Shipping with LiftGate
  • 10-year compressor. 10-year parts warranty*

 

Calculate Heating and Cooling Cost:

Calculate Heating and Cooling Cost

About This Product

This Rheem Classic Series heat pump unit is designed for ground level or rooftop installation. The Rheem RPNL Classic model features cooling efficiencies up to 14 SEER/12.25 EER, and heating efficiencies up to 8.2 HSPF. The higher the SEER level, the greater your energy savings will be over time. This heat pump includes an on demand defrost control. The demand defrost control monitors the outdoor ambient temperature, outdoor coil temperature, and the compressor run-time to determine when a defrost cycle is required.

RHLL Air Handler Details:

Rheem Air Handlers combine money-saving efficiency, quiet operation, and legendary reliability to bring you total peace of mind in home comfort – year after year. Some Air Handlers cost more, some promise more – but nothing performs more reliably. It’s that simple.

The RHLL features GE's new X-13 ECM motor, which provides enhanced SEER performance with Rheem outdoor units. The X-13 motors are high efficiency motors that were developed by General Electric to help manufacturers meet the 13 SEER mandate implemented by the federal government in 2006. They are based on ECM (Electronically Commutated Motor) technology and can contribute to increasing the overall cooling efficiency of a complete HVAC system when used as the curculating air blower motor in a furnace, air handler or packaged unit. GE refers to the X13 motor as a standard ECM motor.

Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil.

The following additional features, plus its energy-saving characteristics, make the RPNL- Heat Pump outdoor units an excellent choice for new construction or upgrading your present system.

Rheem RPNL Classic Features:

  • Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
  • Enhanced Compressor Protection—Features an enhanced defrost control, auto-reset high pressure control, and auto-reset low pressure control to provide compressor protection under abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes experienced with conventional control systems.
  • Factory Charged with R-410A Refrigerant.
  • Copper Tube/Aluminum Fin Coils—Both indoor and outdoor coils.
  • Internal Check Valve—Providesfor quieter refrigerant metering.
  • Refrigerant Metering—TEV accurately meter refrigerant into indoor and outdoor coils.
  • Bi-Directional Filter Drier—Standard on RPNL- *AZ models (shipped – not installed).
  • Service valves are standard on all models.
  • Non-Cycling Reversing Valve—Eliminates discharge noises on each heating cycle.
  • Hot Gas Muffler—Reduces noise in heating cycle.
  • Demand Defrost Control—Provides complete defrost when defrost is required.
  • Drawn Painted Base Pan—For extra corrosion resistance and sound reduction.
  • Strong, attractive cabinet—louvered design protects the coil from damage.
  • Coil design permits compressor operation with the access panel removed.
  • Control box is fully accessible in the upper part of the cabinet, just under the access panel.
  • All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installation.
  • U.L listed & Certified and rated under A.R.I. Standard 240.
  • Compressor compartment offers additional protection from the elements and reduces operating noise.
  • Single speed, 8-pole fan motor is designed for quieter, energy-saving operation.
  • All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus.

RHLL- High Efficiency - With X-13 Blower Motor - Air Handler Features:

  • RHLL feature GE’s new X-13 (ECM) motor which provides enhanced SEER performance.
  • Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
  • Factory-installed high efficiency indoor coil.
  • Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil.
  • Enhanced airflow up to .7" external static pressure.
  • 1.0" foil faced insulation mechanically retained in blowercompartment for excellent thermal and sound performance.
  • Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet UL and cUL requirements for service disconnect.

*Online Registration Require